Grain-oriented silicon steel / Power transformers

Application · Power transformers

CRGO Steel for Power Transformers

Power transformer cores run for decades under near-continuous load, so no-load loss compounds into a real lifetime cost. We supply Hi-B and laser-scribed grain-oriented steel at 0.23–0.30mm, engineered for the lowest core loss and highest permeability in large power cores — built to meet the efficiency levels called for under IEC 60076-1, DOE 10 CFR Part 431, EU Ecodesign Tier 2 and China’s GB 20052.

0.23–0.30 mm gauge range ≤ 0.85 W/kg Hi-B core loss B8 ≥ 1.92 T induction 24 h quotation

Why no-load loss matters here

Loss you pay for every hour, for decades

A distribution transformer cycles with demand; a power transformer often runs near-continuously for 25–40 years. No-load (core) loss is present the entire time the unit is energised, regardless of load — so a small difference in W/kg compounds into a large lifetime energy cost.

This is why utilities and large industrial buyers rarely evaluate transformer bids on purchase price alone. Many specifications apply capitalized loss evaluation — assigning a dollar-per-watt penalty (commonly called “A” and “B” factors under IEEE C57.120 and similar utility practice) to no-load and load losses, then adding that penalty to the purchase price to get a true lifetime cost. Under this method, a transformer with a higher sticker price but lower core loss frequently wins the bid, because the core loss saving over 25+ years outweighs the price difference many times over.

Regulatory efficiency mandates reinforce the same logic. IEC 60076-1 defines the loss and efficiency framework most international specs reference; DOE 10 CFR Part 431 sets minimum efficiency levels for power transformers sold in the US; the EU’s Ecodesign Regulation (EU) 548/2014 Tier 2 does the same for the European market; and China’s GB 20052 sets minimum efficiency grades domestically. All four push core material selection toward Hi-B and laser-scribed CRGO, since Standard CRGO alone often can’t clear the newer efficiency thresholds on large units.

25–40 yr service life Loss runs 24/7 Capitalized loss evaluation Hi-B pays back over time
See Hi-B & laser-scribed grades

What we recommend

Large power cores23ZH90 / 23QG090, 0.23mm
Premium low-loss23QG085, ≤0.85 W/kg
Conventional / cost-sensitiveM4–M6, 27Q120–35Q145
Not sure?Send your rating, we’ll confirm

Efficiency standards that shape specs

Four frameworks buyers spec against

Whichever market you’re building for, one of these usually sets the efficiency floor your core steel needs to clear.

IEC

IEC 60076-1

The international baseline for transformer losses and efficiency, referenced by most non-US, non-EU specs worldwide.

US

DOE 10 CFR Part 431

US federal minimum efficiency levels for distribution and power transformers — Hi-B is common on units sized to clear it comfortably.

EU

Ecodesign (EU) 548/2014 Tier 2

The EU’s current efficiency tier for power transformers, tightened from Tier 1 — pushes core selection toward lower-loss grades.

CN

GB 20052

China’s minimum allowable energy efficiency standard for transformers, with grade tiers similar in spirit to DOE and Ecodesign.

Recommended grades

Grain-oriented lines for power cores

Power transformers most often specify Hi-B; Standard CRGO remains an option where cost outweighs the last fraction of loss.

Hi-B & Laser-Scribed

Domain-refined for the lowest loss and highest permeability — the default choice for large power cores.

  • Thickness0.23 mm
  • Core loss P1.7/50≤ 0.85 W/kg
  • Induction B8≥ 1.92 T
23ZH9023QG08523QG090
View Hi-B CRGO

Standard CRGO

Conventional grain-oriented grades for power cores where budget outweighs marginal loss gains.

  • Thickness0.27–0.35 mm
  • Core loss P1.7/50≤ 0.90 W/kg
  • Induction B8≥ 1.88 T
M4M5M627Q120
View Standard CRGO

Grain-Oriented Hub

Compare all three CRGO lines side by side before you commit to a grade.

  • Thickness range0.10–0.35 mm
  • StandardsGB · EN · JIS · AISI
  • Grade equivalentsCross-referenced
Full range
View CRGO overview

In the field

CRGO in the power transformer core

From coil to wound core — what our Hi-B and Standard CRGO looks like on the way into a transformer.

Hi-B grain-oriented silicon steel coil for power transformer cores
Hi-B CRGO coil, 0.23mm, ready for slitting to core width.
Wound power transformer core built from grain-oriented silicon steel laminations
A wound core stack, laminated from Hi-B CRGO sheet to minimise no-load loss.

Technical requirements

What power transformer specs typically call for

Core loss (no-load loss)Lowest available — Hi-B grades ≤ 0.85–0.90 W/kg at 1.7T/50Hz
Magnetic induction B8≥ 1.90 T preferred for Hi-B, ≥ 1.88 T for Standard CRGO
Thickness0.23mm most common for large power cores; 0.27–0.30mm for mid-size units
Surface insulationC5 or EP-2 glass-film coating, per GB/T 2521 or EN 10107
Stacking factor≥ 0.965 (0.23mm) — affects effective core cross-section
Mill certificationMill test certificate with every order, ISO 9001 / IATF 16949

Sizing a mid-size unit instead? See Distribution Transformers for the more cost-balanced spec — view distribution transformer steel →

How we work

From enquiry to your dock

A simple path from spec to delivery, built for overseas buyers.

1

Send your rating

Transformer kVA rating and target no-load loss, or a drawing.

2

Quote in 24h

Grade recommendation, pricing and availability within one business day.

3

Free samples

Test core loss and stampability, usually within a week.

4

Production & QC

Rolled, slit and tested to grade, with a mill certificate.

5

Export delivery

Moisture-proof packing and ocean freight to your port.

FAQ

CRGO for power transformers

Why do power transformers need Hi-B grades specifically?

Power transformers run near-continuously for decades, so no-load (core) loss is present around the clock regardless of load. Hi-B and laser-scribed grades cut that loss by 5–10% versus Standard CRGO, which compounds into significant energy savings over the transformer’s service life — often justifying the higher material cost.

What is “capitalized loss evaluation” and why does it matter for my grade choice?

Many utility and industrial buyers don’t award transformer bids on price alone. They apply a dollar-per-watt penalty to no-load and load losses (often called “A” and “B” factors) and add that to the purchase price to get a true lifetime cost. A transformer built with lower-loss Hi-B core steel often wins this comparison even at a higher upfront price, because the accumulated loss saving over 25+ years outweighs the difference.

What thickness should I use for a large power transformer core?

0.23mm is the most common choice for large power cores, since thinner laminations reduce eddy-current loss. 0.27–0.30mm is used on mid-size units where the loss penalty is more tolerable and cost matters more.

Can you match the grade on my existing transformer’s core steel?

Yes — send us the grade code or a datasheet from your current supplier and we’ll cross-reference it to our GB, EN, JIS or AISI equivalent and confirm the match.

What’s the lead time for Hi-B CRGO in bulk?

Quotes come within 24 hours. Common Hi-B widths often ship from stock in days; large or non-standard orders typically take a few weeks — tell us your volume and timeline and we’ll confirm.

Do you provide test data with each coil?

Yes — every order ships with a mill test certificate confirming core loss, induction and thickness, produced under ISO 9001 and IATF 16949.

Why buyers choose Zhongxin

Mill-grade CRGO, export-ready service

Wuxi Zhongxin Special Steel Co., Ltd. is a Chinese manufacturer and exporter of grain-oriented silicon steel, serving power transformer makers across Europe, the Americas, Asia and beyond.

200,000 t
annual silicon-steel capacity for stable delivery
5
ISO 9001 · IATF 16949 · RoHS · REACH plus a CNAS-accredited test lab
In-house
laser scribing, annealing & coating for Hi-B grades
24 h
quotations, with free samples in about a week

Send your transformer rating — get a grade recommendation

kVA rating, target no-load loss, or a drawing — we’ll recommend a grade and quote in 24 hours.

滚动至顶部